Features
|
MCR1900-AC
|
MCR1900-DAC
|
MCR1900-DC
|
MCR1900-DDC
|
Slots
|
19 slots for insertion of Perle Unmanaged Media Converter Modules or Managed Media Converter Modules with Chassis Management Module
|
Intelligent Alarm Relay
|
Dry Contact Relay engaged upon monitored chassis
error conditions: power failure, high temperature, backplane voltage
error, fan speed failure
3 amps @24 vDC, Normally open / normally closed contacts on removable terminal blocks
|
Hot-swappable Modules
|
All Media Converter modules, management module and power supplies are hot-swappable
|
Power
|
Nominal input voltage
|
115/230 VAC
|
24/48v DC
|
Input Voltage Range
|
90 - 264 VAC
|
18 - 72v DC
|
Capacity
|
120 watts max.
The single power supply can provide sufficient power for a
chassis that is completely filled with media converter modules
|
240 watts max.
The dual supply provides redundancy for instant fail-over. Power supplies load share
|
120 watts max.
The single power supply can provide sufficient power for a
chassis that is completely filled with media converter modules
|
240 watts max.
The dual supply provides redundancy for instant fail-over. Power supplies load share
|
AC input frequency
|
47 - 63 Hz
|
N/A
|
International Power Line Cords by Model
|
USA: IEC320-C13 to NEMA5-15P
|
Pluggable Terminal block +, - , Gnd with Reverse polarity protection
|
UK: IEC320-C13 to BS1363
|
EU: IEC320-C13 to CEE717 Schuko
|
South Africa / India: IEC320-C13 to BS546
|
Australia: IEC320-C13 to AS3112
|
LEDs
|
Power Supply A Status
|
Power Supply A and B status
|
Power Supply A Status
|
Power Supply A and B status
|
Grounding
|
Dual ground screws for #10 ring terminals or grounding lug connectors provide a reliable chassis ground connection.
|
Environmental Specifications
|
Heat Output ( BTU/HR )
|
17
|
29
|
19 at 24vdc, 25 at 48vdc
|
34 at 24vdc, 49 at 48vdc
|
MTBF (Hours)
|
31,716
|
255,530
|
32,051
|
255,531
|
Operating Temperature
|
0C to 50C, 32F to 122F
|
Storage Temperature
|
-25C to 70C, -13F to 150F
|
Humidity
|
5 to 95% (non-condensing) for both storage and operation.
|
Case
|
SECC Zinc plated sheet metal (1 mm)
|
Ingress Protection Rating
|
IP30 with all slots occupied
|
Altitude
|
up to 3,038 meters ( 10,000 ft)
|
Mounting
|
2U - 19" rack mounting hardware is included
2U - 23" Telcom / ETSI rack mounting hardware is optional
|
Product Weight and Dimensions
|
Weight
|
6.32 kg, 14 lbs
|
7.0 kg, 15.4 lbs
|
6.39 Kg, 14.1 lbs
|
7.14 kg, 15.74 lbs
|
Dimensions
|
356 x 435 x 89 mm, 14 x 17.2 x 3.5 in
|
Packaging
|
Shipping Weight
|
7.76 kg, 17 lbs
|
9.0 kg, 19.8 lbs
|
7.76 kg, 17.11 lbs
|
9.0 kg, 19.8 lbs
|
Shipping Dimensions
|
559 x 482 x 178 mm, 22 x 19 x 7 in
|
Regulatory Approvals
|
Emissions
|
FCC Part 15 Class A, EN55022 Class A
|
CFR47:2003, Chapter 1, Part 15 Subpart B,(USA) Class A
|
ICES-003, Issue 4, February 2004 (Canada)
|
EN55022:1998 + A1:2000 + A2:2003 Class A
|
EN61000-3-2 : 1995, Limits for Harmonic Current Emissions
|
EN61000-3-3 : 1995, Limits of Voltage Fluctuations and Flicker
|
Immunity
|
EN55024:1998 + A1:2001 + A2:2003
|
EN61000-4-2: Electrostatic Discharge
|
EN61000-4-3: RF Electromagnetic Field Modulated
|
EN61000-4-4: Fast Transients
|
EN61000-4-5: Surge
|
EN61000-4-6: RF Continuous Conducted
|
EN61000-4-8: Power-Frequency Magnetic Field
|
EN61000-4-11: Voltage Dips and Voltage Interruptions
|
Safety
|
IEC 60950-1, First Edition (2001-10) and EN60950-1:2001, CB scheme.
|
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL 60950-1,
First Edition April 1st 2003 (Recognized Component)
|
Environmental
|
RoHS - 2002/95/EC Directive
|
WEEE - 2002/96/EC Directive
|
Reach compliant
|
Other
|
ECCN: 5A991A
|
HTSUS Number: 8517.62.0050
|
Perle Lifetime Warranty
|