Power |
Input Supply Voltage |
6 - 30 vDC, unregulated ( 12 vDC Nominal ) |
Current |
0.21 amps |
Power Consumption |
2.5 watts |
Power Connector |
5.5mm x 9.5mm x 2.1mm barrel socket
|
Power Adapter |
Universal AC/DC Adapter |
100-240v AC, regulated DC adapter included |
Indicators |
Power / TST |
This green LED is turned on when power is applied to the media
converter. Otherwise it is off. The LED will blink slowly when in
Loopback test mode. |
Fiber link 1 / Receive activity (LK1) |
This green LED is operational only when power is applied. The
LED is on when the 100Base-X link is on and flashes with a 50% duty
cycle when data is received. |
Fiber link 2 on / Receive activity (LK2) |
This green LED is operational only when power is applied. The
LED is on when the 100Base-X link is on and flashes with a 50% duty
cycle when data is received. |
Switches - accessible through a side opening in the chassis |
Auto-Negotiation |
Auto (default up) - Fiber Negotiation is performed
for both fiber ports. Full and half duplex will be advertised. Pause
will advertise support for Symmetrical and Asymmetrical Pause. Pause
frame will not be acted upon or generated but will be passed through.
Off - Negotiation on both fiber ports will be disabled.
Settings of Link mode and Fiber fault alert will be determined by those
switch settings. Pause frames will not be acted upon or generated but
will continue to be passed through. |
Link Mode |
Smart Link Pass-Through: - (default up) - In
this mode, the link state on one connection is directly reflected
through the media converter to the other connection. If link is lost on
one of the connections, then the other link will be brought down by the
media converter.
Standard: - In this mode the links on both fiber ports
can be brought up and down independently of each other. A loss of link
on either link can take place without affecting the other connection |
Fiber Fault Alert |
Enabled - (default up) - If the media converter
detects a loss of fiber signal on a fiber receiver, it will immediately
disable its fiber transmitter signal. This, in effect, notifies the
remote fiber link partner that an error condition exists on the fiber
connection. The setting of this switch applies to both fiber ports
Disabled: The media converter will not monitor for fiber fault or generate them. |
Remote Loopback #1 |
The media converter can perform a loopback on the link #1 fiber interface.
Disabled (Default - Up)
Enabled - The 1000Base-X receiver is looped to the 1000Base-X transmitter. Link #2's fiber transmitter is taken off the interface |
Remote Loopback #2 |
The media converter can perform a loopback on the link #2 fiber interface.
Disabled (Default - Up)
Enabled - The 1000Base-X receiver is looped to the 1000Base-X transmitter. Link #1's fiber transmitter is taken off the interface |
Fiber Connectors |
1000Base-X |
Available in SC, ST and LC connector models |
Packet Transmission Characteristics |
Bit Error Rate (BER) |
<10 -12 |
Environmental Specifications |
Operating Temperature |
0° C to 50° C (32° F to 122° F) |
Storage Temperature |
minimum range of -25° C to 70° C (-13° F to 158° F) |
Operating Humidity |
5% to 90% non-condensing |
Storage Humidity |
5% to 95% non-condensing |
Operating Altitude |
Up to 3,048 meters (10,000 feet) |
Heat Output ( BTU/HR ) |
8.53 |
MTBF (Hours) |
Without power adaptor: 432,138
With power adaptor: 274,804 |
Mounting |
Din Rail Kit |
Optional |
Wall / Rack Mount Kit |
Optional |
Product Weight and Dimensions |
Weight |
0.3 kg, 0.66 lbs |
Dimensions |
120 x 80 x 26 mm, 4.7 x 3.1 x 1.0 inches |
Packaging |
Shipping Weight |
0.55 kg, 1.2 lbs |
Shipping Dimentions |
170 x 280 x 70 mm, 6.7 x 10.2 x 2.8 inches |
Regulatory Approvals |
Emissions |
FCC Part 15 Class A, EN55022 Class A |
CISPR 22 Class A |
EN61000-3-2 |
Immunity |
EN55024 |
Electrical Safety |
UL 60950-1 |
EN60950 |
CE |
Laser Safety |
EN 60825-1:2007 |
Fiber optic transmitters on this device meet Class 1 Laser safety requirements
per IEC-60825 FDA/CDRH standards and comply with 21CFR1040.10 and 21CFR1040.11. |
Environmental |
RoHS - 2002/95/EC Directive |
WEEE - 2002/96/EC Directive |
Reach compliant |
Other |
ECCN: 5A991A |
HTSUS Number: 8517.62.0050 |
Perle Lifetime warranty |