Power
|
Input Supply Voltage
|
6 - 30 vDC, unregulated ( 12 vDC Nominal )
|
Current
|
0.29 amps
|
Power Consumption
|
3.5 watts
|
Power Connector
|
5.5mm x 9.5mm x 2.1mm barrel socket
|
Power Adapter
|
Universal AC/DC Adapter
|
100-240v AC, regulated DC adapter included
|
Indicators
|
Power / TST
|
This green LED is turned on when power is applied to the media
converter. Otherwise it is off. The LED will blink slowly when in
Loopback test mode.
|
Fiber link 1 / Receive activity (LK1)
|
This green LED is operational only when power is applied. The
LED is on when the 100Base-X link is on and flashes with a 50% duty
cycle when data is received.
|
Fiber link 2 on / Receive activity (LK2)
|
This green LED is operational only when power is applied. The
LED is on when the 100Base-X link is on and flashes with a 50% duty
cycle when data is received.
|
Switches - accessible through a side opening in the chassis
|
Link Pass Through
|
Enabled (Default) - When the state of the receiver is
changed on one of the 100Base-X interfaces it is reflected on the other
100Base-X fiber transmitter.
If disabled, the 100Base-X fiber interfaces operate
independently. Far-End Fault indication on the 100Base-FX fiber
interface has no effect on the other interface.
|
Far-End Fault (FEF)
|
Enabled ( default ), the media converter transmits
the Far-End Fault Indication over the fiber connection whenever a
receive failure is detected. The media converter continuously monitors
the fiber connection and clears the Far-End Fault Indication condition
when a valid signal is received.
Enabled - The 100Base-X receiver is looped to the 100Base-X transmitter. Link #2's fiber transmitter is taken off the interface.
|
Remote Loopback #1
|
The media converter can perform a loopback on the link #1 fiber interface.
Disabled (Default - Up)
Enabled - The 100Base-X receiver is looped to the 100Base-X
transmitter. The 100Base-TX transmitter is taken off the interface.
|
Remote Loopback #2
|
The media converter can perform a loopback on the link #1 fiber interface.
Disabled (Default - Up)
Enabled - The 100Base-X receiver is looped to the 100Base-X
transmitter. Link #1's fiber transmitter is taken off the interface.
|
Cables
|
Fiber Optic Cable
|
Multimode: 62.5 / 125, 50/125, 85/125, 100/140 micron
Single Mode: 9/125 micron (ITu-T 625)
|
Packet Transmission Characteristics
|
Bit Error Rate (BER)
|
<10 -12
|
Environmental Specifications
|
Operating Temperature
|
0 C to 50 C (32 F to 122 F)
|
Storage Temperature
|
minimum range of -25 C to 70 C (-13 F to 158 F)
|
Operating Humidity
|
5% to 90% non-condensing
|
Storage Humidity
|
5% to 95% non-condensing
|
Operating Altitude
|
Up to 3,048 meters (10,000 feet)
|
Heat Output ( BTU/HR )
|
11.9
|
MTBF (Hours)
|
Without power adaptor: 503,679
With power adaptor: 302,090
|
Mounting
|
Din Rail Kit
|
Optional
|
Rack Mount Kit
|
Optional
|
Product Weight and Dimensions
|
Weight
|
0.3 kg, 0.66 lbs
|
Dimensions
|
120 x 80 x 26 mm, 4.7 x 3.1 x 1.0 inches
|
Packaging
|
Shipping Weight
|
0.55 kg, 1.2 lbs
|
Shipping Dimensions
|
170 x 280 x 70 mm, 6.7 x 10.2 x 2.8 inches
|
Regulatory Approvals
|
Emissions
|
FCC Part 15 Class B*, EN55022 Class B*
|
CISPR 22 Class B*
|
EN61000-3-2
|
Immunity
|
EN55024
|
Electrical Safety
|
UL 60950-1
|
EN60950
|
CE
|
Laser Safety
|
EN 60825-1:2007
|
Fiber optic transmitters on this device meet Class 1 Laser
safety requirements per IEC-60825 FDA/CDRH standards and comply with
21CFR1040.10 and 21CFR1040.11.
|
Environmental
|
RoHS - 2002/95/EC Directive
|
WEEE - 2002/96/EC Directive
|
Reach compliant
|
Other
|
ECCN: 5A991A
|
HTSUS Number: 8517.62.0050
|
Perle Lifetime warranty
|