Power
|
Input Supply Voltage
|
Triple voltage 12 / 24 / 48 VDC (9.6 – 60 VDC) input supporting:
a) 2 x Terminal Block power input and
b) 1 x T-Bus power input
|
Current
|
0.9 A (@ 24VDC)
|
Power Consumption
|
2.16 watts (@ 24VDC)
|
Power Connector
|
Dual input Terminal Block and/or T-Bus
|
Indicators
|
Power / TST
|
This green LED is turned on when power is applied to the media converter. Otherwise it is off. The LED will blink fast/slow when in Loopback test mode or hardware error.
|
Fiber link on / Receive activity (LKF)
|
On: Fiber link present. Blinking slowly: Fiber link disabled because of copper link loss. Blinking quickly: Fiber link present and receiving data. Off: No fiber link present
|
Copper link on / Receive activity (LKC)
|
On: Copper link is present. Blinking quickly: Copper link present and receiving data. Blinking slowly: Copper link disabled because of fiber link loss. Off: No copper link present
|
Switches - accessible by sliding the chassis open
|
|
Auto-Negotiation
|
Auto (Default - Up): In this mode of operation the media converter will negotiate Ethernet parameters on the copper connection. This will ensure the most optimal connection parameters will be in effect. If the copper link partner does not support Auto negotiation, the media converter will default to 100 Mbps and Half Duplex mode.
Off: Auto Negotiation should only be turned off, if the copper link partner does not support Auto Negotiation. When the Auto Negotiation switch is set to the OFF position, the media converter will operate at 100 Mbps and Full Duplex mode.
|
Smart Link Pass-Through
|
Smart Link Pass-Through (Default - Up): In this mode, the link state on one connection is directly reflected through the media converter to the other connection. If link is lost on one of the connections, then the other link will be brought down by the media converter. If the installation has a media converter on both ends of the fiber link and both are setup for Link Pass-Through, then a loss of copper link on the far end device will propagate through both media converters and will result in a loss of copper link at the near end device. This would, therefore, resemble a direct copper connection.
Standard Mode (Down): In this mode, the links on the fiber and copper sides can be brought up and down independently of each other. A loss of link on either the fiber ports or copper ports can take place without affecting the other connection
|
Pause
|
Auto (Deafult-Up): When Auto Negotiation has been set to Auto, the media converter will use this setting for its Ethernet parameter negotiation on the copper connection.
Half: The media converter will not negotiate support for the Pause feature.
|
Loopback
|
Disabled (Default-Up): The loopback feature is disabled. This is the normal position for regular operation. The switch must be set to this position for data to pass through the media converter.
Enabled: This is a test mode. All data received on the receive (RX) fiber connection is looped back to the transmit (TX) fiber connection. The state of the copper is not relevant and no data or link status is passed through to the copper side.
|
Far-End Fault (FEF)
|
Enabled (Defualt-Up): If the media converter detects a loss of fiber signal on the fiber receiver, it will immediately send a FEF on the fiber link. This notifies the fiber link partner that an error condition exists on the fiber connection. If the remote media converter is set up for FEF, and the local media converter is set up with Link Pass-Through, a loss of fiber link on either the transmit or receive line will be passed through to the local copper connection to notify the connected device. If the media converter has been set to Link Pass-Through mode, the effect will be the same as FEF since the link loss on the fiber receiver will bring down the copper link, which will in turn cause the transmit fiber link to be brought down.
Disabled: The media converter will not monitor for or generate Far End Fault.
|
Cables and Connectors
|
100Base-TX
|
RJ45 connector, 2 pair CAT 5 (UTP or STP) or better cable
|
Fixed Fiber
|
Dual multimode or single mode ( Duplex ) fiber - SC, ST
Single strand fiber ( Simplex ) – SC, ST
|
Magnetic Isolation
|
1.5kv
|
Fiber Optic Cable
|
Multimode: 62.5 / 125, 50/125, 85/125, 100/140 micron
Single Mode: 9/125 micron (ITu-T 625)
|
Filtering
|
Filtering
|
1024 MAC Addresses
|
Frame Specifications
|
Buffer
|
512 Kbits frame buffer memory
|
Size
|
Maximum frame size of 2048 bytes
|
Packet Transmission Characteristics
|
Bit Error Rate (BER)
|
<10
-12
|
Environmental Specifications
|
Operating Temperature
|
-10 C to 60 C (14 F to 140 F)
|
Storage Temperature
|
-25 C to 70 C (-13 F to 158 F)
|
Operating Humidity
|
5% to 90% non-condensing
|
Storage Humidity
|
5% to 95% non-condensing
|
Operating Altitude
|
Up to 3,048 meters (10,000 feet)
|
Heat Output
( BTU/HR )
|
7.37
|
MTBF (Hours)
|
694,621 (Calculation model based on MIL-HDBK-217-FN2 @ 30 °C)
|
Chassis
|
Molded plastic DIN Rail case with an IP20 ingress protection rating
|
Mounting
|
Din Rail Kit
|
Native
|
Product Weight and Dimensions
|
Weight
|
0.12 kg, 0.26 lbs
|
Dimensions
|
114 x 100 x 22.5mm, 4.5 x 3.9 x 0.88 inches
|
Packaging
|
Shipping Weight
|
0.17 kg, 0.37 lbs
|
Shipping Dimensions
|
145 x 105 x 30 mm, 5.7 x 4.1 x 1.2 inches
|
Regulatory Approvals
|
Emissions
|
FCC 47 Part 15 Class A, EN55032 (CISPR32) Class A
ICES-003
EN61000-6-4 (Emissions for industrial environments)
CISPR 32:2015/EN 55032:2015 (Class A)
CISPR 24:2010/EN 55024:2010
EN61000-3-2
|
Immunity
|
EN55024
EN 61000-4-2 (ESD)
EN 61000-4-3 (RS)
EN 61000-4-4 (EFT)
EN 61000-4-5 (Surge)
EN 61000-4-6 (CS)
EN 61000-4-8 (PFMF)
EN 61000-4-11
IEC/EN 61000-6-2 (General Immunity for Industrial Environments)
|
Electrical Safety
|
UL 61010-1 and UL 61010-2-201 (including CB)
UL/ULC/EN 62368-1 (including CB)
CAN/CSA C22.2 No. 62368-1-14
|
CE
|
Laser Safety
|
EN 60825-1:2007
|
Fiber optic transmitters on this device meet Class 1 Laser safety requirements per IEC-60825 FDA/CDRH standards and comply with 21CFR1040.10 and 21CFR1040.11.
|
Environmental
|
Reach, RoHS and WEEE Compliant
|
Other
|
ECCN: 5A991
|
HTSUS Number: 8517.62.0050
|
Perle Limited Lifetime Warranty
|