Indicators
|
Power / TST
|
This green LED is turned on when power is applied to the media converter. Otherwise it is off. The LED will blink slowly when in Loopback test mode.
|
Fiber link 1 / Receive activity (LK1)
|
This green LED is operational only when power is applied. The LED is on when the 100Base-X link is on and flashes with a 50% duty cycle when data is received.
|
Fiber link 2 on / Receive activity (LK2)
|
This green LED is operational only when power is applied. The LED is on when the 100Base-X link is on and flashes with a 50% duty cycle when data is received.
|
Switches: On-Board (If Auto/Switch strap is set to Switch)
|
Link Pass Through
|
Enabled (Default) - When the state of the receiver is changed on one of the 100Base-X interfaces it is reflected on the other 100Base-X fiber transmitter.
When a Far-End Fault Indication is received on the fiber interface the 100Base-TX transmitter is turned off. When the Far-End Fault Indication is cleared the transmitter is turned back on.
If disabled , the 100Base-X fiber interfaces operate independently. Far-End Fault indication on the 100Base-FX fiber interface has no effect on the other interface.
|
Far-End Fault (FEF)
|
Enabled (Default) - The media converter transmits the Far-End Fault Indication over the fiber connection whenever a receive failure is detected. The media converter continuously monitors the fiber connection and clears the Far-End Fault Indication condition when a valid signal is received.
When Disabled, Far-End Fault Indications are not transmitted regardless of the condition of the receive signal on the 100Base-X fiber connection.
|
Remote Loopback #1
|
The media converter can perform a loopback on the link #1 fiber interface.
Disabled (Default - Up)
Enabled - The 100Base-X receiver is looped to the 100Base-X transmitter. Link #2's fiber transmitter is taken off the interface.
|
Remote Loopback #2
|
The media converter can perform a loopback on the link #2 fiber interface.
Disabled (Default - Up)
Enabled - The 100Base-X receiver is looped to the 100Base-X transmitter. Link #1's fiber transmitter is taken off the interface.
|
Configuration Mode (Strap)
|
Auto (default) enable management module to overwrite hardware switch settings
Switch - Use onboard DIP switches
|
Cables
|
Fiber Optic Cable
|
Multimode: 62.5 / 125, 50/125, 85/125, 100/140 micron
Single Mode: 9/125 micron (ITU-T 625)
|
Packet Transmission Characteristics
|
Bit Error Rate (BER)
|
<10 -12
|
Environmental Specifications
|
Operating Temperature
|
0 C to 50 C (32 F to 122 F)
|
Storage Temperature
|
minimum range of -25 C to 70 C (-13 F to 158 F)
|
Operating Humidity
|
5% to 90% non-condensing
|
Storage Humidity
|
5% to 95% non-condensing
|
Operating Altitude
|
Up to 3,048 meters (10,000 feet)
|
Heat Output
( BTU/Hr )
|
11.9
|
Maximum Power Consumption ( Watts )
|
3.5
|
MTBF (Hours)*
|
484,202
|
Mechanical - Hot Swapping Card
|
Edge Connecter
|
32 pin DIN 41612 / IEC 60603-2 Type B/2 Male. Fist make, last break for ground and power
|
Card insertion and removal
|
Captive thumb screws enable fast insertion and removal. Can be further tighten with a screwdriver.
|
Product Weight
|
Weight
|
0.15 kg, 0.33 lbs
|
Packaging
|
Shipping Weight
|
0.33 kg, .73 lbs
|
Shipping Dimensions
|
203 x 38 x 152 mm, 8 x 1.5 x 6 inches
|
Regulatory Approvals
|
Emissions
|
FCC Part 15 Class A, EN55022 Class A
|
CISPR 22 Class A
CISPR 32:2015/EN 55032:2015 (Class A)
CISPR 24:2010/EN 55024:2010
|
EN61000-3-2
|
Immunity
|
EN55024
|
Electrical Safety
|
UL 60950-1
|
IEC 60950-1(ed 2); am1, am2
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013
|
CE
|
Laser Safety
|
EN 60825-1:2007
|
Fiber optic transmitters on this device meet Class 1 Laser safety requirements per IEC-60825 FDA/CDRH standards and comply with 21CFR1040.10 and 21CFR1040.11.
|
Environmental
|
Reach, RoHS and WEEE Compliant
|
Other
|
ECCN: 5A991
|
HTSUS Number: 8517.62.0050
|
Perle Limited Lifetime Warranty
|