Power |
eXP-1S1110PE |
eXP-4S1110PE |
Unit Powered by |
Local power adapter |
Provides Power to: |
Ethernet |
Power adapter connector |
Barrel or terminal block |
Input Voltage Range from adapter |
46V to 57 |
Input Voltage Range from VDSL (parasitic) |
24 to 57 |
Universal AC Adapter |
56vDC, 75 watt adapter included |
Power Connectors |
5.5mm x 9.5mm x 2.1mm barrel socket and 2 pin terminal Block |
Ethernet |
eXP-1S1110PE |
eXP-4S1110PE |
10/100/1000Base-T Port(s) |
1 port RJ45 Shielded |
4 port RJ45 Shielded |
Auto-MDIX |
Auto-MDIX enables proper operation with either straight-through or crossover cabling |
Distance |
Distance up to 100 meters ( 328 feet ) as per IEEE 802.3 |
Maximum Frame Size |
1522 |
Type of PoE device |
Type 2 PSE ( PoE+ ) IEEE 802.3at |
PoE PSE Maximum Power (Watts) |
Refer to the Power Reach Installation Planning Guide |
PoE PSE RJ45 Cable Pinout |
Alternative A ( default ) on all ports
Alternative B: selectable on port #1
Legacy Cisco Pre-Standard: selectable on port #1
Pins 3,6 Neg, Pins 1,2 Pos
Pins 7,8 Neg, Pins 4,5 Pos
Pins 7,8 Pos, Pins 4,5 Neg |
VDSL – Interlink |
eXP-1S1110PE |
eXP-4S1110PE |
Connector |
Choice of RJ45, BNC or terminal block models for VDSL link connector
- RJ45 – RING pin 4, TIP pin 5 (TIA 568 A/B)
- BNC – Coaxial 75 ohm cable with BNC connector
- Terminal Block – 2 position screw connectors for use with twisted pair telephone, alarm or serial cabling
|
Copper Cabling |
Ethernet Extenders must be connected in pairs
using unconditioned wire between 19 ( 0.9 mm ) and 26 AWG ( 0.44 mm ).
Circuits that run through signal equalization equipment are not
permitted. |
VDSL Line Rate/Reach |
Actual distance and rates experienced will depend
on condition and gauge of wire used. This Rate/Reach table applies to 24
AWG ( 0.5 MM ) twisted pair wiring on RJ45 (RJ) and terminal block (TB)
models.
High Speed Asymmetric |
Reach ( Distance ) |
VDSL Rate ( Mbps ) |
feet |
meters |
Downstream |
Upstream |
250 |
76 |
195 |
105 |
500 |
152 |
182 |
98 |
1000 |
305 |
141 |
63 |
1500 |
457 |
93 |
45 |
2000 |
610 |
66 |
30 |
2500 |
762 |
53 |
12 |
3000 |
914 |
44 |
8 |
3500 |
1000 |
36 |
5 |
High Speed Symmetric |
Reach ( Distance ) |
VDSL Rate ( Mbps ) |
feet |
meters |
Downstream |
Upstream |
250 |
76 |
190 |
110 |
500 |
152 |
180 |
105 |
1000 |
305 |
122 |
83 |
1500 |
457 |
84 |
50 |
2000 |
610 |
64 |
26 |
2500 |
762 |
53 |
10 |
3000 |
914 |
42 |
7 |
3500 |
1000 |
36 |
4 |
Long Reach Symmetric |
Reach ( Distance ) |
VDSL Rate ( Mbps ) |
feet |
meters |
Downstream |
Upstream |
250 |
76 |
76 |
57 |
1000 |
305 |
74 |
49 |
2500 |
762 |
52 |
10 |
4000 |
1219 |
28 |
2 |
5500 |
1676 |
15 |
1.5 |
7000 |
2134 |
8 |
1.4 |
8500 |
2591 |
5 |
1.3 |
10000 |
3000 |
2 |
0.9 |
Long Reach Asymmetric |
Reach ( Distance ) |
VDSL Rate ( Mbps ) |
feet |
meters |
Downstream |
Upstream |
250 |
76 |
78 |
16 |
1000 |
305 |
76 |
16 |
2500 |
762 |
52 |
10 |
4000 |
1219 |
28 |
2 |
5500 |
1676 |
15 |
1.5 |
7000 |
2134 |
8 |
1.4 |
8500 |
2591 |
5 |
1.3 |
10000 |
3000 |
2 |
0.9 |
|
Power Budget |
The amount of available power at the PoE+ PD is dependent on the scenario planned.
Refer to the Power Reach Installation Planning Guide |
Indicators |
eXP-1S1110PE |
eXP-4S1110PE |
Power / TST |
This green LED is turned on when power is applied
to the Ethernet Extender. Otherwise it is off. The LED will blink when
in Loopback test mode. |
CO - Local |
Ethernet Extender is operating in CO VDSL mode |
CPE - remote |
Ethernet Extender is operating in CPE VDSL mode |
ILNK |
Indicates Link Status and activity on the Interlink (VDSL) port |
ETH |
Indicates link status and activity on Ethernet port(s). |
PSE Status |
This LED will signify the status of the PSE
function. Using multi-color and blinking the unit will show the
following status for the PSE;
GREEN — Solid: The PSE has successfully detected a compliant PD
and is applying power over the UTP (for legacy pin out simply show
active power when applied)
YELLOW — Solid: The PSE is not active. This means the PSE has been configured to provide power, but the PD is :
- Not connected
- Has not detected a compliant PD and is not applying power
- PSE has turned off power for Reset function
OFF — PSE function switch disabled
RED — Blinking: Error Conditions
- Capacitance too High — 1 blink
- Resistance too Low or short circuit — 2 blinks
- Resistance too high or open circuit — 3 blinks
|
Switches |
eXP-1S1110PE |
eXP-4S1110PE |
Access |
Switch settings are accessible through a side opening in the chassis |
Rate/Reach |
Two switches enable the user to select the right balance between speed and distance for their environment. |
Signal to Noise Ratio |
Selectable Signal to Noise Ratio (SNR) of 6dB or
9dB. The higher SNR number provides better impulse noise protection but
lowers performance. |
Auto-Negotiation (802.3u) control on Port 1 |
Enabled (Default) - The Ethernet Extender uses 802.3u Auto-negotiation on the 10/100/1000Base-T interface. It is set to advertise full duplex.
Disabled - The Ethernet Extender sets the port according to the position of the speed and duplex switches. |
Force Ethernet Speed on Port 1 |
When Auto-Negotiation switch is disabled, a fixed speed can be forced on port 1
|
Force Ethernet Duplex on Port 1 |
When Auto-Negotiation switch is disabled, Full or half Duplex can be forced on port 1
|
Link Mode* |
Standard (Default) – The 10/100/1000Base-T link remains active independent of the state of the Ethernet link on its remote peer.
Link Pass-Through- the state of the 10/100/1000Base-T
Ethernet connection is “passed through” or propagated across the VDSL
link to the 10/100/1000Base-T Ethernet link on its remote Ethernet
Extender peer. |
Interlink Fault Feedback* |
Enabled – A loss of VDSL link will drop the 10/100/1000 Ethernet port on each end until the link recovers
Disabled ( Default ) - The state of the VDSL link is not propagated to the 10/100/1000Base-T port |
Loopback |
Enabled – The VDSL interlink will perform a loopback function, retransmitting all received Ethernet frames back to its remote peer.
Disabled (Default - Up) |
PD Reset ( Port 1 ) |
When enabled ( down ), the Ethernet Extender will
upon loss of link on the VDSL Interlink port, turn off PSE output power
to the PD device for 2 seconds then turn the power back on. The power
remains on until the VDSL link transitions from up to down again.
When PD Power Reset is disabled ( default ), loss of VDSL link has no effect on power supplied to the PD device. |
Environmental Specifications |
eXP-1S1110PE |
eXP-4S1110PE |
Operating Temperature |
0 C to 50 C (32 F to 122 F) |
Storage Temperature |
minimum range of -25 C to 70 C (-13 F to 158 F) |
Operating Humidity |
5% to 90% non-condensing |
Storage Humidity |
5% to 95% non-condensing |
Operating Altitude |
Up to 3,048 meters (10,000 feet) |
Current mA |
114 @ 56vdc |
163 @ 56vdc |
Unit Power Consumption watts |
6.4 |
9.1 |
Heat Output
( BTU/HR ) |
21.84 |
31.05 |
MTBF with power adapter (Hours)** |
75,029 |
72,416 |
MTBF without power adapter (Hours)** |
300,472 |
262,530 |
Mounting |
eXP-1S1110PE |
eXP-4S1110PE |
Wall/Desk |
Standard |
Din Rail Kit |
Optional |
Rack Mount Kit |
Optional |
Product Weight and Dimensions |
eXP-1S1110PE |
eXP-4S1110PE |
Weight |
0.58 Kg, 1.3 lbs |
0.61Kg, 1.34 lbs |
Dimensions |
163 x 116 x 37 mm, 6.4 x 4.6 x 1.46 inches |
Packaging |
eXP-1S1110PE |
eXP-4S1110PE |
Shipping Weight |
1.27 Kg, 2.8 lbs |
1.3 Kg, 2.86 lbs |
Shipping Dimensions |
20 x 30 x 7 cm, 7.9 x 11.8 x 2.8 inches |
Regulatory Approvals |
eXP-1S1110PE |
eXP-4S1110PE |
Emissions |
EN 55022 |
CISPR 22 |
IEC/EN 61000-3-2 |
IEC/EN 61000-3-3 |
Immunity |
EN 55024:2010 |
CISPR 24:2010 |
IEC/EN 61000-4-2 |
IEC/EN 61000-4-3 |
IEC/EN 61000-4-4 |
IEC/EN 61000-4-5 |
IEC/EN 61000-4-6 |
IEC/EN 61000-4-8 |
IEC/EN 61000-4-11 |
Electrical Safety |
EN60950-1 |
IEC 60950-1 |
UL 60950-1 |
CSA C22.2 No. 60950-1 |
Environmental |
Reach, RoHS and WEEE Compliant |
Other |
ECCN: 5A991A |
HTSUS Number: 8517.62.0050 |
Perle Lifetime warranty |