INJ 2101-T
27030118
|
INJ 2111-T
27030138
|
INJ 2102-T
27030128
|
INJ 2112-T
27030148
|
INJ 2103-T
10040658
|
INJ 2113-T
10040668
|
Serial Interface
|
Interface 1
|
Ethernet
|
Connection method
|
Screw terminal block
|
IDC connection
|
Push-in connection
|
Transmission length
|
100 m (including patch cables)
|
Conductor cross section solid min.
|
0.14 mm˛
|
0.2 mm˛
|
Conductor cross section solid max.
|
1.5 mm˛
|
0.34 mm˛
|
1.5 mm˛
|
Conductor cross section flexible min.
|
0.14 mm˛
|
0.2 mm˛
|
Conductor cross section flexible max.
|
1.5 mm˛
|
0.34 mm˛
|
1.5 mm˛
|
Conductor cross section AWG min.
|
28
|
26
|
Conductor cross section AWG max.
|
16
|
22
|
16
|
Torque
|
0.22 Nm...0.25 Nm
|
|
Stripping length
|
5 mm
|
|
8 mm
|
Pin assignment
|
1:1
|
Basic functions
|
PSE/Midspan, compliant with IEEE 802.3af, at
|
Serial transmission speed
|
10/100/1000 Mbps
|
Output nominal voltage
|
54 V DC (PoE)
|
Output power
|
30 W
|
60 W
|
30 W
|
60 W
|
30 W
|
Maximum output power
|
40 W
|
75 W
|
40 W
|
75 W
|
40 W
|
Interface 2
|
Ethernet
|
Connection method
|
RJ45 CAT5e
|
Wire diameter incl. insulation
|
|
1.6 mm (Terminal block is tested with PVC insulation - other insulation materials available on request)
|
|
Ambient conditions
|
Ambient temperature (operation)
|
-40 °C ... 75 °C
|
Ambient temperature
(storage/
transport)
|
-40 °C ... 85 °C
|
Permissible humidity (operation)
|
10 % ... 95 % (non-condensing)
|
Altitude
|
5000 m (For restrictions see manufacturer's declaration)
|
Degree of protection
|
IP20 (Manufacturer's declaration)
|
|
|
General
|
Electrical isolation
|
VCC // SCM + FE // PoE
|
Test voltage data interface/power supply
|
1.5 kV AC (50 Hz, 1 min.)
|
Electromagnetic compatibility
|
Conformance with EMC Directive 2014/30/EU
|
Mounting position
|
Vertical
|
Net weight
|
324.72 g
|
Housing material
|
Plastic
|
Color
|
Gray
|
MTTF
(SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week,
8 hours a day))
|
1510 Years
|
1797 Years
|
1510 Years
|
1797 Years
|
1510 Years
|
MTTF
(SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week,
12 hours a day))
|
661 Years
|
733 Years
|
661 Years
|
733 Years
|
661 Years
|
MTTF
(SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week,
24 hours a day))
|
256 Years
|
283 Years
|
256 Years
|
283 Years
|
256 Years
|
Conformance
|
CE-compliant
|
UL, USA
|
UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4
|
UL, USA/Canada
|
Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4
|
Class I, Division 2, Groups A, B, C, D
|
UL, Canada
|
CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16
|
Standards and Regulations
|
Electromagnetic compatibility
|
Conformance with EMC Directive 2014/30/EU
|
Type of test
|
Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
|
Test result
|
10 Hz ... 57 Hz, amplitude ±3.5 mm, 57 Hz ... 150 Hz, 5g
|
Type of test
|
Shock in acc. with EN 60068-2-27/IEC 60068-2-27
|
Test result
|
30g for 11 ms, three shocks in each spatial direction
|
Type of test
|
Continuous shock according to EN 60068-2-27/IEC 60068-2-27
|
Test result
|
10g for 16 ms, 1000 shocks in each spatial direction
|
Standards/
regulations
|
EN 61000-4-2
|
Contact discharge
|
± 6 kV (Test Level 3)
|
Indirect discharge
|
± 6 kV
|
Standards/
regulations
|
EN 61000-4-3
|
Frequency range
|
80 MHz ... 3 GHz (Test Level 3)
|
Standards/
regulations
|
EN 61000-4-4
|
Comments
|
Criterion B
|
Standards/
regulations
|
EN 61000-4-5
|
Signal
|
± 1 kV (Data line, asymmetrical)
|
± 2 kV (I/O cable on field side only, asymmetric)
|
Standards/
regulations
|
EN 61000-4-6
|
Frequency range
|
0.15 MHz ... 80 MHz
|
Standards/
regulations
|
IEC 61643-21
|
IEC test classification
|
C2
|
Conformance
|
CE-compliant
|
UL, USA
|
UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4
|
UL, USA/Canada
|
Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4
|
Class I, Division 2, Groups A, B, C, D
|
UL, Canada
|
CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16
|
Noxious gas test
|
ISA-S71.04-1985 G3 Harsh Group A
|
Function
|
Designation
|
Shield current monitoring
|
Switch-on threshold
|
≥ 30 mA
|
Local diagnostics
|
Yellow LED
|
Precision
|
± 5 %
|
Response time
|
3 s
|
Continuous shield current
|
≤ 2 A
|
Power consumption
|
270 mW (Shield current monitoring)
|
Dimensions
|
Width
|
30.2 mm
|
Height
|
130 mm
|
Depth
|
120 mm
|
Note
|
Utilization restriction
|
EMC: class A product, see manufacturer's declaration in the download area
|
Power Supply
|
Nominal supply voltage
|
24 V DC
|
48 V DC
|
Supply voltage range
|
18 V DC ... 57 V DC
|
Max. current consumption
|
2.1 A
|
4.2 A
|
2.1 A
|
4.2 A
|
2.1 A
|
1.4 A (24 V DC)
|
2.73 A (24 V DC)
|
1.4 A (24 V DC)
|
2.73 A (24 V DC)
|
1.4 A (24 V DC)
|
0.7 A (48 V DC)
|
1.34 A (48 V DC)
|
0.7 A (48 V DC)
|
1.34 A (48 V DC)
|
0.7 A (48 V DC)
|
Power consumption
|
≤ 75 W
|
Protective circuit
|
Reverse polarity protection
|
Conductor cross section flexible max.
|
4.00 mm˛
|
Conductor cross section flexible min.
|
0.75 mm˛
|
Conductor cross section solid max.
|
4.00 mm˛
|
|
|
Conductor cross section solid min.
|
0.75 mm˛
|
Conductor cross section AWG max.
|
12
|
Conductor cross section AWG min.
|
20
|
Approvals
|
|
- cULus Listed
- cUL Listed
- UL Listed
|
|
|
Environmental Product Compliance
|
REACH SVHC
|
Lead 7439-92-1
|
China RoHS
|
Environmentally Friendly Use Period = 50
|
Environmentally friendly use period: unlimited = EFUP-e
|