PP-RJ-RJ-F
27030208
|
PP-RJ-SC-F
27030218
|
PP-RJ-SCC-F
27030228
|
PP-RJ-IDC-F
27030238
|
Serial interface
|
Interface 1
|
Ethernet interface, 10/100/1000Base-T(X) according to IEEE 802.3u
|
Connection method
|
RJ45 socket
|
Screw terminal block
|
Push-in connection
|
IDC connection
|
Transmission length
|
100 m (including patch cables)
|
Pin assignment
|
1:1
|
Serial transmission speed
|
10/100/1000 Mbps
|
Maximum output current
|
725 mA (PoE)
|
Current carrying capacity
|
≤ 1.5 A (≤ 60 W (PoE+))
|
Maximum output power
|
60 W
|
Interface 2
|
Ethernet interface, 10/100/1000Base-T(X) according to IEEE 802.3u
|
Connection method
|
RJ45 CAT5e
|
Conductor cross section solid min.
|
|
0.14 mm²
|
0.2 mm²
|
0.14 mm²
|
Conductor cross section solid max.
|
|
1.5 mm²
|
0.34 mm²
|
Conductor cross section flexible min.
|
|
0.14 mm²
|
0.2 mm²
|
0.14 mm²
|
Conductor cross section flexible max.
|
|
1.5 mm²
|
0.34 mm²
|
Conductor cross section AWG min.
|
|
28
|
26
|
Conductor cross section AWG max.
|
|
16
|
22
|
Torque
|
|
0.22 Nm ... 0.25 Nm
|
|
Stripping length
|
|
5 mm
|
8 mm
|
|
Wire diameter incl. insulation
|
|
1.6 mm (Terminal block is tested with PVC insulation - other insulation materials available on request)
|
Ambient conditions
|
Ambient temperature (operation)
|
-40°C ... 75°C
|
Ambient temperature (storage/transport)
|
-40°C ... 85°C
|
Permissible humidity (operation)
|
10 % ... 95 % (non-condensing)
|
Altitude
|
5000 m (For restrictions see manufacturer's declaration) / 2000 m (ATEX approval)
|
Degree of protection
|
IP20 (Manufacturer's declaration)
|
General
|
Electrical isolation
|
FE // Ethernet
|
Electromagnetic compatibility
|
Conformance with EMC Directive 2014/30/EU
|
Net weight
|
124.2 g
|
Housing material
|
Plastic
|
Color
|
Gray
|
MTTF
|
3281 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day))
|
3268 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day))
|
3281 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day))
|
1245 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25 % (5 days a week, 12 hours a day))
|
1238 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25 % (5 days a week, 12 hours a day))
|
1245 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day))
|
472 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day))
|
468 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day))
|
472 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day))
|
Degree of pollution
|
2
|
Overvoltage category
|
II
|
Conformance
|
CE-compliant
|
ATEX
|
II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!)
|
UL, USA
|
UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4
|
UL, USA/Canada
|
Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4 / Class I, Div. 2, Groups A, B, C, D
|
UL, Canada
|
CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16
|
Standards and Regulations
|
Electromagnetic compatibility
|
Conformance with EMC Directive 2014/30/EU
|
Type of test
|
Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
|
Test result
|
10 Hz ... 57 Hz, amplitude ±3.5 mm, 57 Hz ... 150 Hz, 5g
|
Type of test
|
Shock in acc. with EN 60068-2-27/IEC 60068-2-27
|
Test result
|
30g for 11 ms, three shocks in each spatial direction
|
Type of test
|
Continuous shock according to EN 60068-2-27/IEC 60068-2-27
|
Test result
|
10g for 16 ms, 1000 shocks in each spatial direction
|
Standards/regulations
|
EN 61000-4-2
|
Contact discharge
|
± 6 kV (Test Level 3)
|
Indirect discharge
|
± 6 kV
|
Standards/regulations
|
EN 61000-4-3
|
Frequency range
|
80 MHz ... 3 GHz (Test Level 3)
|
Standards/regulations
|
EN 61000-4-4
|
Comments
|
Criterion B
|
Standards/regulations
|
EN 61000-4-5
|
Signal
|
± 1 kV (Data line, asymmetrical)
|
Standards/regulations
|
EN 61000-6-4 / EN 61000-4-6
|
Frequency range
|
0.15 MHz ... 80 MHz
|
Standards/regulations
|
DIN EN 61643-21
|
Rated insulation voltage
|
85 V DC
|
IEC test classification
|
C2
|
Conformance
|
CE-compliant
|
ATEX
|
II 3 G Ex nA nC IIC T4 Gc X
|
UL, USA
|
UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4
|
UL, USA/Canada
|
Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4 / Class I, Div. 2, Groups A, B, C, D
|
UL, Canada
|
CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16
|
Noxious gas test
|
ISA-S71.04-1985 G3 Harsh Group A
|
Function
|
Designation
|
Shield current monitoring
|
Switch-on threshold
|
≥ 30 mA
|
Local diagnostics
|
Yellow LED
|
Precision
|
± 5 %
|
Response time
|
3 s
|
Continuous shield current
|
≤ 1.5 A
|
Power consumption
|
270 mW (Shield current monitoring)
|
Impedance
|
≤ 1 Ω
|
Voltage
|
≤ 10 V
|
Dimensions
|
Width
|
23.8 mm
|
Height
|
101.3 mm
|
Depth
|
86 mm
|
Note
|
Utilization restriction
|
|
1
|
Power supply
|
Supply voltage range
|
36 V DC ... 52 V DC 10 % (via PoE (for shield current monitoring))
|
36 V DC ... 52 V DC 10 % (via PoE)
|
42 V DC ... 57 V DC (With UL approval)
|
Approvals
|
- cULus Listed
- cUL Listed
- UL Listed
|
Environmental Product Compliance
|
China RoHS
|
Environmentally friendly use period: unlimited = EFUP-e
|
Environmentally Friendly Use Period = 50
|
Environmentally friendly use period: unlimited = EFUP-e
|
REACH SVHC
|
|
Lead 7439-92-1
|