Moxa’s 86M series modules with ch-to-ch isolated DIs, ch-to-ch isolated DOs, relays, and AOs provide more I/O options for the ioPAC 8600 series. Combined with 85M modules, enough options are now available to allow users to select the best I/O combination for their target application. All 86M modules are designed for railway industry applications, and as such are compliant with EN 50121-3-2, EN 50121-4, and EN 50155. In addition, the modules support a wide operating temperature range of -40 to 75°C.
86M-1832D-T Specifications
|
• Inputs and Outputs
|
Digital Inputs
|
8 channels
|
Isolation
|
To system: 3k VDC or 2k Vrms Channel to channel: 1k VDC
|
• Digital Inputs
|
Sensor Type
|
Wet contact (NPN or PNP)
|
I/O Mode
|
DI, counter, or frequency
|
Wet Contact
|
NPN: • On: 0 to 3 VDC • Off: 10 to 30 VDC PNP: • Off: 0 to 3 VDC • On: 10 to 30 VDC
|
Counter Frequency
|
5 kHz
|
Digital Filtering Time Interval
|
Software selectable (by 0.1 ms)
|
• Physical Characteristics
|
Wiring
|
I/O cable, max. 16 AWG
|
Connector
|
Spring type terminal block
|
• Environmental Limits
|
Operating Temperature
|
-40 to 75°C
|
• Power Requirements
|
Power Consumption
|
0.3 W
|
• MTBF (mean time between failures)
|
Time
|
1,149,108 hrs
|
Database
|
Telcordia (Bellcore)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- 86M-1832D-T: 8 DIs, sink/source, 24 VDC, ch-to-ch isolation, channel LEDs
- 86M-2830D-T: 8 DOs, sink, 24 VDC, ch-to-ch isolation, channel LEDs
- 86M-2604D-T: 6 relays, form A (N.O.), channel LEDs
- 86M-4420-T: 4 AOs, 0 to 10 V, -10 to 10 V, 0 to 20 mA, or 4 to 20 mA
|
|
|
|
|
|
|