The ABC-01-P-M12 is designed for system backup and restoration to enhance maintenance efficiency and reduce system downtime in railway applications, including rolling stock and wayside installations. The ABC-01-P-M12 Automatic Backup Configurator tool can be used to save and load the configuration of Moxa’s ToughNet managed Ethernet switches and wireless APs/bridges/clients through the RS-232 console port. The ABC-01-P-M12 can be continuously plugged in to Moxa’s Ethernet switches and wireless APs/bridges/clients while the devices are operating, and makes it easier to back up system parameters and manage configurations. With the ABC-01-P-M12, you can quickly configure a replacement switch (of the same model).
The ABC-01-P-M12 is compliant with mandatory sections of EN 50155, covering operating temperature, surge, ESD, and vibration, as well as conformal coating, making the ABC-01-P-M12 suitable for a variety of industrial applications.
Documentation
PDF Data Sheet
PDF Quick Installation Guide
• Interface
|
Connectors
|
RS-232 M12 port
|
• Basic Operation
|
Storage Capacity
|
64 KB
|
• Power Requirements
|
Input Voltage
|
3 to 5 VDC, power input via RS-232 RTS
|
• Physical Characteristics
|
Housing
|
Aluminum
|
IP Rating
|
IP67 protection
|
Dimensions
|
55 mm x Ø20 mm (2.17 in x Ø0.79 in)
|
Weight
|
35 g (0.08 lb)
|
• Environmental Limits
|
Operating Temperature
|
-40 to 75°C (-40 to 167°F)
|
Storage Temperature
|
-40 to 85°C (-40 to 185°F)
|
Ambient Relative Humidity
|
5 to 95 % (non-condensing)
|
Altitude
|
2000 m
|
• Standards and Certifications
|
EMI
|
CISPR 32, FCC Part 15B Class A
|
EMS
|
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 20 V/m (80 MHz to 1 GHz) IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8
|
Rail Traffic
|
(for plug in installations) EN 50155*, EN 50121-4, EN 45545-2
|
*This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here www.moxa.com/doc/specs/EN_50155_Compliance.pdf
|
Shock
|
EN 50155, IEC 61373
|
Freefall
|
IEC 60068-2-31
|
Vibration
|
EN 50155, IEC 61373
|
• MTBF (mean time between failures)
|
Time
|
19,563,216 hrs
|
Standard
|
Telcordia SR332
|
• Warranty
|
Warranty Period
|
5 years
|
Details
|
See www.moxa.com/warranty
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- Plug-n-Play system configuration backup and restoration
- Rugged design to enhance reliability
- Supports Moxa’s managed Ethernet switches and wireless APs/bridges/clients
- Designed to be continuously plugged in to Moxa’s managed Ethernet switches and wireless APs/bridges/clients
- Complies with all EN 50155 mandatory test items*
|
|
|
|
|
|
|