The EDS-205/208 series of industrial Ethernet switches are entry-level industrial 5 and 8-port Ethernet switches that support IEEE 802.3/802.3u/802.3x with 10/100M, full/half-duplex, MDI/MDIX auto-sensing RJ45 ports. The EDS-205/208 switches are rated to operate at temperatures ranging from -10 to 60°C, and are rugged enough for switchesany harsh industrial environment. The switches can be easily installed on a DIN-Rail as well as in distribution boxes. The DIN-Rail mounting capability, wide operating temperature, and the the IP30 housing with LED indicators make the plug-and-play EDS-205/208 switches easy to use and reliable.
-
Standards
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for flow control
-
10/100BaseT(X) Ports (RJ45 connector)
Auto MDI/MDI-X connection
Full/Half duplex mode
-
100BaseFX Ports (multi-mode SC connector)
-
100BaseFX Ports (multi-mode ST connector)
-
Optical Fiber
-
Optical Fiber
-
Processing Type
-
MAC Table Size
-
Packet Buffer Size
-
Input Voltage
-
Input Current
EDS-208: 0.12 A @ 24 VDC
EDS-208-M Series: 0.2 A @ 24 VDC
-
Operating Voltage
-
Connection
1 removable 3-contact terminal block(s)
-
Overload Current Protection
-
Reverse Polarity Protection
-
Housing
-
IP Rating
-
Dimensions
40 x 100 x 86.5 mm (1.57 x 3.94 x 3.41 in)
-
Weight
-
Installation
-
Operating Temperature
-10 to 60°C (14 to 140°F)
-
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
-
Ambient Relative Humidity
5 to 95% (non-condensing)
-
Safety
-
EMC
-
EMI
CISPR 32, FCC Part 15B Class A
-
EMS
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
IEC 61000-4-5 Surge: Power: 1 kV; Signal: 1 kV
IEC 61000-4-6 CS: 3 V
IEC 61000-4-8 PFMF
-
Shock
-
Vibration
-
Freefall
-
Time
EDS-208: 401,624 hrs
EDS-208-M Series: 368,353 hrs
-
Standards
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- 10/100BaseT(X) (RJ45 connector), 100BaseFX (multi-mode, SC/ST connector)
- IEEE802.3/802.3u/802.3x support
- Broadcast storm protection
- DIN-Rail mounting ability
- -10 to 60°C operating temperature range
|
|
|
|
|
|
|