|
|
|
|
The IMC-101G industrial Gigabit media converters are designed to provide reliable and stable 10/100/1000BaseT(X) to 1000BaseSX/LX/LHX/ZX media conversion in harsh industrial environments. The IMC-101G's industrial design is excellent for keeping your industrial automation applications running continuously, and each IMC-101G converter comes with a relay output warning alarm to help prevent damage and loss. All IMC-101G models are subjected to a 100% burn-in test, and are available in models that support a standard operating temperature range of 0 to 60°C, and an extended operating temperature range of -40 to 75°C.
• Technology
|
Standards
|
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX IEEE 802.3ab for 1000BaseT(X) IEEE 802.3z for 1000BaseSX/LX/LHX/ZX
|
• Interface
|
RJ45 Ports
|
10/100/1000BaseT(X)
|
Fiber Ports
|
1000BaseSFP slot
|
LED Indicators
|
PWR1, PWR2, FAULT, 10/100M (TP port), 1000M (TP and Fiber port)
|
DIP Switches
|
Port break alarm mask, Link Fault Pass-Through, SFP Auto/Force
|
Alarm Contact
|
One relay output with current carrying capacity of 1 A @ 24 VDC
|
• Optical Fiber
|
Multi-mode Transmission Distance
|
1000BaseSX:
• 0 to 500 m, 850 nm (50/125 µm, 400 MHz*km) • 0 to 275 m, 850 nm (62.5/125 µm, 200 MHz*km) 1000BaseLX: • 0 to 1100 m, 1310 nm (50/125 µm, 800 MHz*km) • 0 to 550 m, 1310 nm (62.5/125 µm, 500 MHz*km)
|
Single-mode Transmission Distance
|
1000BaseLX: 0 to 10 km, 1310 nm (9/125 µm, 3.5 PS/(nm*km))
1000BaseLHX: 0 to 40 km, 1310 nm (9/125 µm, 3.5 PS/(nm*km)) 1000BaseZX: 0 to 80 km, 1550 nm (9/125 µm, 19 PS/(nm*km))
|
• Physical Characteristics
|
Housing
|
Metal, IP30 protection
|
Dimensions
|
53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
|
Weight
|
630 g
|
Installation
|
DIN-Rail mounting, wall mounting (with optional kit)
|
• Environmental Limits
|
Operating Temperature
|
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
|
Storage Temperature
|
-40 to 85°C (-40 to 185°F)
|
Ambient Relative Humidity
|
5 to 95% (non-condensing)
|
• Power Requirements
|
Input Voltage
|
24 VDC (12 to 48 VDC), redundant inputs
|
Input Current
|
110 mA @ 24 VDC
|
Connection
|
Removable terminal block
|
Overload Current Protection
|
2.5 A
|
Reverse Polarity Protection
|
Present
|
• Standards and Certifications
|
Safety
|
UL 508
|
Hazardous Location
|
UL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2 Ex nC nL IIC T4, IECEx
|
EMC
|
CE, FCC
|
EMI
|
FCC Part 15 Subpart B Class A, EN 55022 Class A
|
EMS
|
EN 61000-4-2 (ESD) Level 3,
EN 61000-4-3 (RS) Level 3, EN 61000-4-4 (EFT) Level 3, EN 61000-4-5 (Surge) Level 2, EN 61000-4-6 (CS) Level 3, EN 61000-4-8, EN 61000-4-11
|
Shock
|
IEC 60068-2-27
|
Freefall
|
IEC 60068-2-32
|
Vibration
|
IEC 60068-2-6
|
Green Product
|
RoHS, CRoHS, WEEE
|
• MTBF (mean time between failures)
|
Time
|
500,540 hrs
|
Database
|
Telcordia (Bellcore), GB
|
• Warranty
|
Warranty Period
|
5 years
|
Details
|
See
http://www.moxa.com/support/warranty.htm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- 10/100/1000BaseT(X) and 1000BaseSX/LX/LHX/ZX supported
- Link Fault Pass-Through (LFP) (media converters should work as a pair)
- Power failure, port break alarm by relay output
- Redundant power input
- -40 to 75°C operating temperature range (T models)
- Designed for hazardous locations
|
|
|
|
|
|
|