The IMC-101 industrial media converters provide industrial grade media conversion between 10/100BaseT(X) and 100BaseFX (SC/ST connectors). The IMC-101’s reliable industrial design is excellent for keeping your industrial automation applications running continuously, and each IMC-101 converter comes with a relay output warning alarm to help prevent damage and loss. The IMC-101 media converters are designed for harsh industrial environments, such as in hazardous locations (Class 1, Division 2/Zone 2, DNV, and GL Certification), and comply with FCC, TV, UL, and CE standards. The IMC-101 series is available in models that support an operating temperature of 0 to 60˚C, and an extended operating temperature of -40 to 75˚C. All IMC-101 series are subjected to a 100% burn-in test.
Technology
|
Standards
|
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
|
• Interface
|
RJ45 Ports
|
10/100BaseT(X)
|
Fiber Ports
|
100BaseFX (SC/ST connectors)
|
LED Indicators
|
PWR1, PWR2, FAULT, 10/100M (TP port), 100M (Fiber port), FDX/COL (Fiber port)
|
DIP Switches
|
100BaseFX Full/Half duplex selection, port break alarm mask
|
Alarm Contact
|
One relay output with current carrying capacity of 1 A @ 24 VDC
|
• Optical Fiber
|
|
• Physical Characteristics
|
Housing
|
Metal, IP30 protection
|
Dimensions
|
53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
|
Weight
|
630 g
|
Installation
|
DIN-Rail mounting, wall mounting (with optional kit)
|
• Environmental Limits
|
Operating Temperature
|
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
|
Storage Temperature
|
-40 to 85°C (-40 to 185°F)
|
Ambient Relative Humidity
|
5 to 95% (non-condensing)
|
• Power Requirements
|
Input Voltage
|
12 to 45 VDC redundant inputs
|
Input Current
|
160 mA @ 24 VDC
|
Connection
|
Removable terminal block
|
Overload Current Protection
|
1.1 A
|
Reverse Polarity Protection
|
Present
|
• Standards and Certifications
|
Safety
|
UL 508, UL 60950-1
|
Hazardous Location
|
UL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2 Ex nC IIC
|
EMC
|
CE, FCC
|
EMI
|
FCC Part 15 Subpart B Class A, EN 55022 Class A
|
EMS
|
EN 61000-4-2 (ESD) Level 3,
EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 3,
EN 61000-4-5 (Surge) Level 2,
EN 61000-4-6 (CS) Level 3,
EN 61000-4-8,
EN 61000-4-11
|
Marine
|
DNV, GL
|
Shock
|
IEC 60068-2-27
|
Freefall
|
IEC 60068-2-32
|
Vibration
|
IEC 60068-2-6
|
Green Product
|
RoHS, CRoHS, WEEE
|
• MTBF (mean time between failures)
|
Time
|
401,000 hrs
|
Database
|
MIL-HDBK-217F, GB 25°C
|
• Warranty
|
Warranty Period
|
5 years
|
Dimensions (unit = mm)
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- 10/100BaseT(X) auto-negotiation and auto-MDI/MDI-X
- Link Fault Pass-Through (LFP) (media converters should work as a pair)
- Power failure, port break alarm by relay output
- Redundant power inputs
- -40 to 75°C operating temperature range (T models)
- Designed for hazardous locations (Class 1 Div. 2/Zone 2)
|
|
|
|
|
|
|