Moxa’s
ioLogik E2200 is a new type of Ethernet micro RTU controller, which is a
PC-based data acquisition and control device that uses proactive,
event-based reporting to control I/O devices. Unlike traditional RTUs,
which are passive and must poll for data, Moxa’s ioLogik E2200 series
with Active OPC Server makes seamless connection with SCADA systems a
reality. In addition, SNMP is used for communicating with an NMS
(Network Management System) for IT field users. The I/O status of an
Ethernet micro RTU controller can be reported and controlled
automatically on-site based on user specified conditions. This
report-by-exception approach, which is new to PC-based monitoring,
requires far less bandwidth than traditional polling methods.
The
ioLogik E2200 Micro RTU supports simple and powerful Click&Go™
technology to deliver event-driven reports and allow alarm messages to
be sent by email, TCP/UDP, and SMNP Trap with real-time stamps. With
built-in Click&Go™ intelligence, the ioLogik E2200 micro RTU can be
used for simple output control when it is triggered by input status,
without the need for a PC controller. The ioLogik E2200 micro RTU
reports I/O status automatically based on user-specified conditions.
This report by-exception approach requires far less bandwidth than the
traditional polling approach.
• LAN
|
Ethernet
|
1 x 10/100 Mbps, RJ45
|
Protection
|
1.5 KV magnetic isolation
|
Protocols
|
Modbus/TCP, TCP/IP, UDP, DHCP, Bootp, SNMP, HTTP, CGI, SNTP, SMTP
|
• Serial Communication
|
Interface
|
RS-485-2w: Data+, Data-, GND (3-contact terminal block)
|
Serial Line Protection
|
15 KV ESD for all signals
|
• Serial Communication Parameters
|
Parity
|
None
|
Data Bits
|
8
|
Stop Bits
|
1
|
Flow Control
|
None
|
Baudrate
|
1200 to 115200 bps
|
Protocol
|
Modbus/RTU
|
• Inputs and Outputs
|
Analog Inputs
|
8 channels
|
Analog Outputs
|
2 channels
|
• Analog Input
|
Type
|
Differential input
|
Resolution
|
16 bits
|
I/O Mode
|
Voltage / Current
|
Input Range
|
±150 mV, ±500 mV, ±5 V, ±10 V, 0 to 20 mA, 4 to 20 mA
|
Accuracy
|
±0.1% FSR @ 25°C
±0.3% FSR @ -10 and 60°C
|
Sampling Rate
|
All Channel:
• 10 samples/sec for voltage
• 6 samples/sec for current
•Per Channel:
• 1.25 samples/sec for voltage
• 0.75 samples/sec for current
Singe Channel
• 1.25 samples/sec for voltage
• 0.75 samples/sec for current
|
Input Impedance
|
900K ohms (min.)
|
Built-in Resistor for Current Input
|
120 ohms
|
Isolation
|
3K VDC or 2K Vrms
|
• Analog Output
|
Resolution
|
12 bits
|
Output Range
|
0 to 10 V, 4 to 20 mA
|
Drive Voltage
|
15 VDC for current output
|
Accuracy
|
±0.1% FSR @ 25°C,
±0.3% FSR @ -10 and 60°C
|
Load Resistor
|
Less than 250 ohms
|
• Power Requirements
|
Power Input
|
24 VDC nominal, 12 to 36 VDC
|
Power Consumption
|
198 mA @ 24 VDC
|
• Physical Characteristics
|
Wiring
|
I/O cable max. 14 AWG
|
Dimensions
|
115 x 79 x 45.6 mm (4.53 x 3.11 x 1.80 in)
|
Weight
|
under 250 g
|
Mounting
|
DIN-rail or wall
|
• Environmental Limits
|
Operating Temperature
|
-10 to 60°C (14 to 140°F)
|
Storage Temperature
|
-40 to 85°C (-40 to 185°F)
|
Ambient Relative Humidity
|
5 to 95% (non-condensing)
|
Altitude
|
Up to 2000 m and higher altitude on demand
|
• Standards and Certifications
|
Safety
|
UL 508
|
EMI
|
EN 61000-3-2; EN 61000-3-3; EN 61000-6-4;
FCC Part 15, Subpart B, Class A
|
EMS
|
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,
EN 61000-4-5, EN 61000-4-6, EN 61000-4-8,
EN 61000-4-11, EN 61000-6-2
|
Shock
|
IEC 60068-2-27
|
Freefall
|
IEC 60068-2-32
|
Vibration
|
IEC 60068-2-6
|
Green Product
|
RoHS, CRoHS, WEEE
|
• MTBF (mean time between failure)
|
Time
|
155,941 hrs
|
Database
|
Telcordia (Bellcore)
|
• Warranty
|
Warranty Period
|
5 years
|
Details
|
See www.moxa.com/warranty
|
Dimensions (unit = mm)
Pin Assignment
I/O (left to right)
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- Front-end intelligence that supports 24 Click&Go™ rules
- Active Messaging with real-time stamp, including SMS, SNMP Trap with I/O status, TCP, and email
- Supports SNMPv1/v2c/v3 protocol
- I/O peer-to-peer function
- Built-in web console
- PC utility: Auto detection of installed modules
- Windows/WinCE VB/VC.NET and Linux C APIs
|
|
|
|
|
|
|