Introduction
The MGate 5103 is an industrial Ethernet gateway for Modbus RTU/ASCII/TCP, EtherNet/IP, and PROFINET network communications. To integrate existing Modbus devices onto a PROFINET network, use the MGate 5103 as a Modbus master/slave or EtherNet/IP adapter to collect data and exchange data with PROFINET devices. The latest exchange data will be stored in the gateway. The gateway will convert stored Modbus or EtherNet/IP data into PROFINET packets so the PROFINET IO Controller can control or monitor field devices.
Easy Configuration via Web Console The MGate 5103 Series comes with an illustrated Quick Setup guide designed to make configuration easy. With Quick Setup, you can easily access protocol conversion modes and finish the configuration in a few steps. The MGate 5103 Series also supports a GSDML export function. GSDML files can be imported into PROFINET PLCs to save time on PLC configuration.
Modbus RTU/ASCII/TCP Protocol Traffic Monitor MGate 5103 gateways support Modbus RTU/ASCII/TCP Protocol Traffic Monitor for easy troubleshooting, especially during the installation stage. Communication issues could be caused by incorrect software parameters, such as slave IDs and register addresses, that were entered incorrectly, or an incorrect command configuration. With Modbus RTU/ASCII/TCP Protocol Traffic Monitor, you can check the captured data and easily identify the root cause.
Maintenance Functions MGate 5103 gateways support a system log function that records events in the MGate; users can easily review log data remotely through the web console. The gateways also support status monitoring and fault protection functions. The status monitoring function notifies a PLC/DCS/SCADA system when a Modbus device gets disconnected or does not respond, in which case the process PLC/DCS gets the status of each end device and then issues alarms to notify operators.
Documentation
Data Sheet
PDF Quick Start Guide
PDF User Manual
-
microSD Slot
Up to 32 GB (SD 2.0 compatible)
-
Contact Current Rating
Resistive load: 2 A @ 30 VDC
-
10/100BaseT(X) Ports (RJ45 connector)
2
Auto MDI/MDI-X connection
-
Magnetic Isolation Protection
-
Industrial Protocols
EtherNet/IP Adapter (Slave), Modbus TCP Client (Master), Modbus TCP Server (Slave), PROFINET IO Device (Slave)
-
Configuration Options
Device Search Utility (DSU), Web Console, Telnet Console
-
Management
ARP, DHCP Client, DNS, HTTP, HTTPS, SMTP, SNMP Trap, SNMPv1/v2c/v3, TCP/IP, Telnet, SSH, UDP
-
MIB
-
Time Management
-
Console Port
RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)
-
Baudrate
-
Connector
-
Data Bits
-
Flow Control
RTS Toggle (RS-232 only), RTS/CTS
-
No. of Ports
-
Parity
None, Even, Odd, Space, Mark
-
RS-485 Data Direction Control
ADDCŪ (automatic data direction control)
-
Serial Standards
-
Stop Bits
-
Pull High/Low Resistor for RS-485
1 kilo-ohm, 150 kilo-ohms
-
Terminator for RS-485
-
Isolation
-
RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
-
RS-422
-
RS-485-2w
-
RS-485-4w
-
Configuration Options
-
Industrial Protocols
Modbus RTU/ASCII Master, Modbus RTU/ASCII Slave
-
Functions Supported
1, 2, 3, 4, 5, 6, 15, 16, 23
-
Input Data Size
-
Max. No. of Commands
-
Mode
-
Output Data Size
-
Functions Supported
1, 2, 3, 4, 5, 6, 15, 16, 23
-
Max. No. of Client Connections
-
Max. No. of Commands
-
Max. No. of Server Connections
-
Input Data Size
-
Mode
-
Output Data Size
-
Input Data Size
-
Max. No. of IO Controller Connections
-
Mode
-
Output Data Size
-
CIP Objects Supported
Identity, Message Router, Assembly, Connection Manager, TCP/IP interface, Ethernet link, Port
-
Input Data Size
-
Max. No. of Scanner Connections
1 (for read-only), 1 (for read/write)
-
Mode
-
Output Data Size
-
Input Current
-
Input Voltage
-
Power Connector
Screw-fastened Euroblock terminal
-
Housing
-
IP Rating
-
Dimensions
36 x 105 x 140 mm (1.42 x 4.14 x 5.51 in)
-
Weight
-
Operating Temperature
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
-
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
-
Ambient Relative Humidity
5 to 95% (non-condensing)
-
Safety
-
EMC
-
EMI
CISPR 32, FCC Part 15B Class B
-
EMS
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
IEC 61000-4-8 PFMF
-
Hazardous Locations
ATEX, Class I Division 2, IECEx
-
Freefall
-
Shock
-
Vibration
IEC 60068-2-6
IEC 60068-2-64
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- Protocol conversion between Modbus, EtherNet/IP, and PROFINET
- Supports PROFINET IO device
- Supports Modbus RTU/ASCII/TCP master/client and slave/server
- Supports EtherNet/IP Adapter
- Effortless configuration via web-based wizard
- Built-in Ethernet cascading for easy wiring
- Embedded traffic monitoring/diagnostic information for easy troubleshooting
- microSD card for configuration backup/duplication and event logs
- Status monitoring and fault protection for easy maintenance
- Serial port with 2 kV isolation protection
- -40 to 75°C wide operating temperature models available
- Supports redundant dual DC power inputs and 1 relay output
- Security features based on IEC 62443
|
|
|
|
|
|
|