The PTC-101 Ethernet-to-fiber media converters convert from
10/100BaseT(X) to 100BaseFX. Models are available with either SC, ST, or
LC connectors. The PTC-101 converters eliminate the need for additional
wiring, and support IEEE 802.3 and IEEE 802.3u/x protocols with
10/100M, full/half-duplex, and MDI/MDI-X auto-sensing to provide a total
solution for your industrial Ethernet networks. The PTC-101 is
compliant with the essential sections of EN 50155, covering operating
temperature, power input voltage, surge, ESD and vibration.
Technology |
Standards |
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X), 100BaseFX |
• Interface |
RJ45 Ports |
10/100BaseT(X) |
Fiber Ports |
100BaseFX (SC/ST/LC connectors) |
LED Indicators |
PWR1, PWR2, Fiber Link, 10/100M (TP port) |
DIP Switches |
|
Alarm Contact |
One relay output with current carrying capacity of 1 A @ 24 VDC (LV model only) |
• Optical Fiber |
|
• Physical Characteristics |
Housing |
Metal, IP30 protection |
Dimensions |
152.15 x 123.46 x 66.65 mm (5.99 x 4.86 x 2.62 in) |
Weight |
Product only: 690 g
Packaged: 875 g |
• Environmental Limits |
Operating Temperature |
-40 to 85°C (-40 to 185°F) |
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
Conformal Coating |
Available upon request |
• Power Requirements |
Input Voltage |
|
Connection |
Removable terminal block |
Overload Current Protection |
1.6 A (protects against two signals shorted together) |
Reverse Polarity Protection |
Protects against V+/V- reversal |
• Standards and Certifications |
Safety |
UL 60950-1 |
EMC |
CE, FCC |
EMI |
FCC Part 15 Subpart B Class A, EN 55022 Class A |
EMS |
EN 61000-4-2 (ESD) Level 4,
EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 4,
EN 61000-4-5 (Surge) Level 4,
EN 61000-4-6 (CS) Level 3,
EN 61000-4-8 (PFMF) Level 5,
EN 61000-4-11 |
Power Automation |
IEC 61850-3, IEEE 1613 |
Rail Traffic |
EN 50155, EN 50121-4 |
Freefall |
IEC 60068-2-32 |
Vibration |
IEC-61850-3, IEC-60870-2-2 |
Green Product |
RoHS, CRoHS, WEEE |
Note |
Refer to the "Environmental Type Tests" table below for more detailed information. |
• MTBF (mean time between failures) |
Time |
1,211,613 hrs |
Database |
Telcordia (Bellcore), GB |
• Warranty |
Warranty Period |
5 years |
Dimensions
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- 10/100BaseT(X) auto-negotiation and
auto-MDI/MDI-X
- Link Fault Pass-Through (LFP)
- Power failure alarm by relay
output (LV model only)
- -40 to 85°C operating temperature
range
- Redundant dual DC power inputs
- Integrated high-reliability power
supply eliminates the need for external power transformer
|
|
|
|
|
|
|