*The TCC-82 ships with (2) 50 cm USB power cords (CBL-USBAP-50).
The TCC-82 provides full electrical isolation for bi-directional
serial communication between two RS-232 devices in a compact,
industrial grade package. Both sides of an RS-232 connection are
isolated optically to provide perfect protection against lightning
surges, accidental high voltage shorts, and ground loops. The built-in,
wide range isolators are tested to ensure that they can withstand more
than 4 KV rms input to output for 1 minute. This means that the TCC-82
not only meets the requirements of general serial data communications,
but also the high standards required by industrial automation and
medical applications. The TCC-82 protects the TxD and RxD data lines,
and also protects the RTS and CTS handshake lines for a total of 4
isolated channels to provide complete protection of your RS-232
applications.
External Power Source Not Required
The TCC-82 supports port-powered operation, which means that it can
obtain power directly from the attached serial devices. Power is
obtained from the RS-232 TxD, RTS, or DTR lines, regardless of whether
the signal is high or low, eliminating the need for an external power
supply. However, external power can be used if handshake lines are not
available, if the serial cable is too long, or if the serial device is
a low powered device. For external power, the TCC-82 can use a 5 to 12
VDC adaptor or a USB power cord. Note that both sides of the connection
are powered independently, so if necessary, one side can rely on port
power and the other on an external power source. When installing the
TCC-82, we recommend that you connect all output signals. The TCC-82
obtains power from these signals even if they are not used by your
system. Care should be taken when choosing the external power supply if
your application requires the full 4 KV of isolation. Most commercial
power supplies provide only 1500 VAC isolation between the primary and
secondary windings. If you are using external power for both sides of
the TCC-82, make sure that separate power sources are used, each with
sufficient isolation protection.
Serial Communication
|
Connectors
|
DB9 male and DB9 female
|
Baudrate
|
50 bps to 921.6 Kbps
|
Signals
|
RS-232: TxD, RxD, RTS, CTS, GND
(Loop-back wiring: DTR to DSR and DCD)
|
ESD Protection
|
15 KV for all signals
|
Optical Isolation
|
4 KV for 1 minute
|
• Physical Characteristics
|
Housing
|
ABS
|
Dimensions
|
42 x 80 x 23.6 mm (1.65 x 3.15 x 0.93 in)
|
Weight
|
60 ± 5 g
|
• Environmental Limits
|
Operating Temperature
|
0 to 60°C (32 to 140°F)
|
Storage Temperature
|
-20 to 75°C (-4 to 167°F)
|
Ambient Relative Humidity
|
5 to 95% (non-condensing)
|
• Power Requirements
|
Source of Input Power
|
RS-232 port (TxD, RTS, DTR) or power input jack
|
Input Voltage
|
5 to 12 VDC
|
Power Consumption
|
20 mA @ 5 V
|
• Standards and Certifications
|
Safety
|
UL 60950-1
|
EMC
|
CE, FCC
|
EMI
|
FCC Part 15 Subpart B Class B
|
EMS
|
EN 61000-4-2 (ESD) Level 2,
EN 61000-4-3 (RS) Level 2,
EN 61000-4-4 (EFT) Level 2,
EN 61000-4-5 (Surge) Level 2,
EN 61000-4-6 (CS) Level 2,
EN 61000-4-8 (SFMF) Level 1
|
Green Product
|
RoHS, CRoHS, WEEE
|
• MTBF (mean time between failures)
|
Time
|
959,780 hrs
|
Database
|
MIL-HDBK-217F
|
• Warranty
|
Warranty Period
|
5 years
|
Dimensions
Pin Assignments
|
|
|